Development of an animal-free methodology for mechanical performance assessment of engineered skin substitutes


Published: 12 February 2020
Abstract views:
1843


PDF:
577
Publisher's note
All claims expressed in this article are solely those of the authors and do not necessarily represent those of their affiliated organizations, or those of the publisher, the editors and the reviewers. Any product that may be evaluated in this article or claim that may be made by its manufacturer is not guaranteed or endorsed by the publisher.

Authors

  • Alessandra Aldieri PolitoBIOMed Lab, Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin; Interuniversity Center for the promotion of the 3Rs principles in teaching and research, Italy.
  • Mara Terzini PolitoBIOMed Lab, Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin; Interuniversity Center for the promotion of the 3Rs principles in teaching and research, Italy.
  • Diana Massai PolitoBIOMed Lab, Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin; Interuniversity Center for the promotion of the 3Rs principles in teaching and research, Italy.
  • Cristina Bignardi PolitoBIOMed Lab, Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin; Interuniversity Center for the promotion of the 3Rs principles in teaching and research, Italy.
  • Alberto Audenino PolitoBIOMed Lab, Department of Mechanical and Aerospace Engineering, Politecnico di Torino, Turin; Interuniversity Center for the promotion of the 3Rs principles in teaching and research, Italy.

Functional substitutes for the treatment of skin wounds are nowadays widely available thanks to the progress in skin tissue engineering. However, the performance of the existing substitutes in terms of mechanical behavior, which is a determinant for their success, still does not match the native tissue. Since the mechanical behavior of skin is governed by dermis, an in-depth investigation of human dermis mechanics would be pivotal for integrating the design and validation of skin substitutes. In the perspective of reducing and replacing animal experiments through validated alternative tools, an accurate in silico constitutive model describing the human dermis mechanics is presented. Biaxial tests were performed on human dermis samples, and resulting data were used for setting the constitutive parameters of the model, able to reliably describing the mechanical properties of the native tissue, and to be compared with the mechanical behavior of skin substitutes attainable through the same procedure.


Aldieri, A., Terzini, M., Massai, D., Bignardi, C., & Audenino, A. (2020). Development of an animal-free methodology for mechanical performance assessment of engineered skin substitutes. Biomedical Science and Engineering, 1(1). https://doi.org/10.4081/bse.103

Downloads

Download data is not yet available.

Citations

Most read articles by the same author(s)